Gas meter location regulations

Fox Thermal Manufactures A Full Line Of Advanced Thermal Mass Flow Meter s – Learn More! Award-Winning Flow Meter Technology. Call To Order Or Speak With An Expert Now!

Where is the gas meter located? What is gas meter regulation? Minimum Clearance Distance to Gas Meter or Regulator Vent: Gas meter location: Front wall (front presumed facing public access), or within feet of side wall (see corner clearances) Regulator relief vent distance from any outside building corner: inches.

Meter should be located in the front or within feet of the front corner of the home. If you have a septic system, it must be clearly marked prior to the installation of a new service line. Requesting a New Natural Gas Meter. In or near a traffic area unless adequately protected from passing vehicles by bollards, a concrete barrier , or equivalent. The National Electric Code (NEC) prohibits the use of underground gas piping as a grounding electrode.

The meter must be located 3’ away from a driveway or vehicular traffic. Meters exposed to vehicular damage may require guard posts in accordance with State of Virginia Fire Prevention Code requirements. There shall be a minimum distance of feet of unobstructed working space , measured from the meter face , in front of all electric and natural gas meters.

We require a 3-foot minimum separation between natural gas and electric facilities.

The preferred termination of service laterals is on the outside of a building. If house is on corner with road running down side of house, then box can be on this wall or on back wall, but if on back wall same regs apply with regard distance and gate etc. If a building is next to a footpath (i.e. no garden etc.) the meter may be located inside the property. This is subject to a low pressure gas connection being available. When the meter is located inside , it should be located as close as possible to the gas entry point of the building.

Gas meter room location and piping must conform to all current federal, state, and local codes including Code of Federal Regulations (CFR. Part 192), “Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards,” and the National Fuel Gas Code (NFPA 54). If you are unable to meet the meter location requirements in this handout, contact SJG for further assistance. This document is derived from multiple SJG standards, codes, regulations , and best practices. SJG reserves the right to designate gas meter locations so that they comply with all applicable codes and SJG standards.

Location Considerations for Gas Meter Room The Gas Meter Room shall be located on external walls of the building at ground level with access directly from outside. The metering room shall be located in a separate masonry room, sealed from the main building, and used exclusively for the purposes of gas metering. Each meter existing within a building must be located in a ventilated place more than three feet from any source of ignition or heat source that might damage the meter.

Trench bottom shall be level, free of rocks, and deep enough to provide a mini-. Gas meters shall not be located under interior stairways or show windows. Sand padding with suitable rock-free material is required six inches below and.

Pipe in the trench shall not be in contact with or any closer than inches to any. Fill Your Cart With Color Today! Great Plains Natural Gas requires a 4-foot clear zone in front of the gas meter.

A gas meter room is a space within a building that is solely used to house natural gas metering equipment.

On an exception basis, gas meters and regulators may be installed in a specially designed gas meter room. INSTALLATION RESPONSIBILITIES This section provides information on the restrictions and conditions placed on where gas meter boxes may be located. Before services and meters can be installe the following conditions must be met: The construction site and building foundation must be back-filled to within of final grade. The gas meter location must be clearly marked.

For example, the property we have purchased has a gas box meter located outside of the premises – in the shed with a lock just off the public roa is this allowed? Please include any plans for future additions. This is for two primary reasons, to protect the gas meter from the weather and to help secure it from being tampered with or damaged.

There are a range of different gas meter housings on the market which vary dependant on pressure in the gas mains, the location , and the size. Gas alterations can be required for a number of reasons, from relocating a gas meter to increasing or reducing the supply or moving pipework to accomodate renovations or alterations.

Leave a Reply

Your email address will not be published. Required fields are marked *